Introduction & Context

The multiple‑impeller spacing calculation determines the axial arrangement of several agitator impellers within a cylindrical mixing tank. Proper spacing ensures that each impeller operates in a hydrodynamically independent region, avoids mechanical interference, and provides adequate power transfer to the fluid. This analysis is routinely applied in the design of large‑scale stirred‑tank reactors, fermenters, and chemical‑process vessels where high‑shear mixing and uniform residence time are required.

Methodology & Formulas

1. Reynolds number (turbulent regime check)

\[ Re = \frac{\rho \, N \, d^{2}}{\mu} \]

2. Froude number (vortex formation check)

\[ Fr = \frac{N^{2} \, d}{g} \]

3. Spacing factor (α) enforcement

The user‑provided spacing factor α_input is limited to a minimum value α_min to prevent impeller overlap:

\[ \alpha = \max\!\left(\alpha_{\text{input}},\; \alpha_{\text{min}}\right) \]

4. Centre‑to‑centre spacing (S)

\[ S = \alpha \, d \]

5. Axial positions of impeller centres (zi)

\[ z_{i}= C_{b} + \frac{d}{2} + i\,S \qquad i = 0,1,\dots ,N_{\text{imp}}-1 \]

6. Stack height (Hstack)

\[ H_{\text{stack}} = d + (N_{\text{imp}}-1)\,S \]

7. Axial coverage of the tank (η)

\[ \eta = \frac{H_{\text{stack}}}{H} \]

8. Power per impeller (Pimp) using the Rushton correlation

\[ P_{\text{imp}} = P_{0}\,\rho\,N^{3}\,d^{5} \]

9. Total shaft power (Ptotal)

\[ P_{\text{total}} = N_{\text{imp}} \, P_{\text{imp}} \]

Validity Checks

Parameter Expression Limit / Criterion Action / Note
Reynolds number \(Re\) \(Re \ge Re_{\text{crit}}\) Warn if \(Re < Re_{\text{crit}}\) – turbulent correlation may be invalid.
Froude number \(Fr\) \(Fr \le Fr_{\text{crit}}\) Note if \(Fr > Fr_{\text{crit}}\) – vortex formation may require baffles.
Spacing factor (α) \(\alpha_{\text{input}}\) \(\alpha_{\text{min}} \le \alpha_{\text{input}} \le \alpha_{\text{max}}\) Adjust to \(\alpha\) if outside range to avoid overlap.
Axial coverage \(\eta\) \(\eta \ge \eta_{\text{min}}\) Warn if \(\eta < \eta_{\text{min}}\) – consider larger spacing or more impellers.
Top clearance \(C_{\text{top}} = H - \bigl(C_{b}+H_{\text{stack}}\bigr)\) \(C_{\text{top}} \ge C_{\text{top,min}}\) Warn if \(C_{\text{top}} < C_{\text{top,min}}\) – increase tank height or reduce impeller count/size.